EasyManua.ls Logo

Hi-Target ZTS-320 Series - Resection

Hi-Target ZTS-320 Series
97 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
9.2.3 Resection .
Enter the coordinate of the first point:
To input, see reference in „STA of „Coordinate
measurement‟. Press „ENT‟ to enter the measurement page of
„Resection-No.1‟
Choose the method of angle or distance for the resection. If
choosing distance mode, the instrument will start to measure.
After a successful measurement, the system will display „Next P‟
Press soft key „Next P‟. Repeat the process above. After
measuring three points, soft key „Calc‟ will appear on the screen.
If do not need resection, then pressing„Calc‟ to display the
result of resection.
Resection-N0.3
VZ: 77°18′30″
HR: 180°00′01″
HD: 4.978m
T.H: 1.000
Next P Calc
Resection-N0.3
VZ: 17°18′30″
HR: 10°00′01″
HD: 4.978m
T.H: 1.000
Mode Angle Dist
Resection-N0.1
VZ: 77°18′30″
HR: 180°00′01″
HD: 4.978 m
T.H: 1.000
Mode Angle Dist
Resection-N0.1
>Pt.name:
Code:
T.H: 1.000
[]Select file
Save K.Pt Info. M.Pt.

Table of Contents