9.3.8 The instrument as a memory disc
You can use Mini USB connector to connect the instrument
to PC machine. The USB port is below the SD card port. Start the
instrument after connection.
The total station is now recognized as a memory disc by PC
machine. After opening the instrument file on PC machine, you
can view the files saved in the instrument . Also, you can copy
files to PC machine. Disconnect the PC machine to operate the
instrument normally.
Note: never delete or alter the two „.sys‟ files in the
instrument. Do not copy senseless files that have nothing to do
with the total station measurements.
9.4 Programs
9.4.1 Remote height (REM)
REM is adequate for measuring the height of target when
the prism cannot be placed at the target point. Under REM mode,
you can place the prism on any point along the plumb line of the
target point to obtain the height of target .
VD
Prism height
prism
P
Target point
C
There are two modes for REM measurement: „with TH‟
and „without TH‟. You can select „with TH‟ mode when you need
the altitude from ground to target , otherwise „without TH‟ when
you need the altitude from any reference point to target .
With TH:
1. Enter the height of instrument and the height of target
firstly.
2. Press „ENT‟ to enter the interface of „REM-Prism