VertX EVO V1000 User Guide, 71000-901, Rev. A.4
Page 16 of 25 July 2016
Appendix: A Troubleshooting
A.1 System Status
System Status provides a technician with a method of validating the VertX installation, field
wiring and installed devices. Perform the System Status at any time after the VertX controller
has been installed and power is available. In addition, a technician may perform a system
status as many times as necessary.
Upon startup, the System Status window will discover all connected and powered V100-
Series devices attached to the controller and displays the inputs, outputs, and host status.
Reference the Legend to determine the meaning of the different images.
By clicking Add Unconfigured you can configure the V1000 for the attached panels and
readers. The assumption is that two readers are attached to any V100 interface panel and
that both readers are Wiegand card only. Once the configuration is complete, the VertX
software will refresh.
Once the window refreshes, a Restore Previous button becomes available.
The Restore Previous button enables the technician to use the previously saved
configuration.
A.2 Supplemental Configuration
Supplemental Configuration provides the ability to view and configure system inputs and
outputs.
These buttons provide navigation to the following functionality:
Configure - configure inputs, outputs and door characteristics for a V1000, V100,
V200, and V300.
System Time - update System Time
Update System – updates the interface board’s firmware
A.3 Configure
Configure provides the ability to view and modify system inputs and outputs and door
characteristics.
Upon successful validation, the Save button will write modified values to the interface panel.