VertX EVO V2000 Installation Guide, 72000-901, Rev. A.5
July 2016 Page 11 of 22
4.2 Virtual Port
Contact a VertX controller by directly connecting the computer to the controller using an
Ethernet cable. By default, every controller is configured to respond to a fixed address:
169.254.242.121.
Ensure you are running a Windows 2000 or XP computer. 1.
Disconnect your Windows computer from its hub or network. 2.
Connect the Windows computer to the controller with an Ethernet cable. 3.
Select the Windows Start > Run. 4.
Enter ipconfig /renew. Wait for DHCP to timeout (approximately 60 sec). 5.
The computer will acquire a 169.254.x.x address.
Access a web browser and enter 169.254.242.121 into the Address field. The 6.
controller is now accessible through this Virtual Port.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HID VertX EVO V2000 and is the answer not in the manual?

HID VertX EVO V2000 Specifications

General IconGeneral
Inputs8 supervised inputs
Reader InterfacesWiegand, Clock-and-Data
HousingMetal
CommunicationRS-485
Power Supply12-24 VDC
Operating Temperature-40° to 70° C
Humidity5% to 95% non-condensing
CertificationsUL 294, CE, FCC