3. Parameter setting
3-17
P03-15*
+ 10[V] RPM
Unit
rpm
Display range
0.0 ~ 9999.9
Manufactured
default
Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the +10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-15)
Voltage
P03-16*
-10[V] RPM
Unit
rpm
Display range
-9999.9 ~ 0.0
Manufactured
default
-Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the -10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-16)
Voltage