3. Parameter setting
3-16
P03-04
Load COMPEN
Unit
%
Display range
0.0 ~ 100.0
Manufactured
default
0.0
Speed/position
control
This sets the external load compensation coefficient to improve the response of the servo
motor for the sudden load change.
P03-05
SC Loop Gain 1
Unit
Hz
Display range
0.0 ~ 1000.0
Manufactured
default
By capacity
Speed/position
control
P03-06
SC TC 1
Unit
ms
Display range
0.0 ~ 10000.0
Manufactured
default
By capacity
Speed/position
control
P03-07
SC Loop Gain 2
Unit
Hz
Display range
0.0 ~ 1000.0
Manufactured
default
By capacity
Speed/position
control
P03-08
SC TC 2
Unit
ms
Display range
0.0 ~ 10000.0
Manufactured
default
By capacity
Speed/position
control
P03-09
Analog CMD TC
Unit
ms
Display range
0.0 ~ 2000.0
Manufactured
default
0.0
Speed control
P03-10
ACCEL Time
Unit
ms
Display range
0.0 ~ 90000.0
Manufactured
default
0.0
Speed control
P03-11
DECEL Time
Unit
ms
Display range
0.0 ~ 90000.0
Manufactured
default
0.0
Speed control
P03-12*
S-Mode TC
Unit
ms
Display range
0.0 ~ 9000.0
Manufactured
default
0.0
Speed control
P03-13
In Speed Range
Unit
rpm
Display range
0.0 ~ 9999.9
Manufactured
default
10.0
Speed control
P03-14
Zero Speed Range
Unit
rpm
Display range
0.0 ~ 9999.9
Manufactured
default
10.0
Speed control