EasyManuals Logo

Higen FDA7030 User Manual

Default Icon
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
3. Parameter setting
3-17
P03-15*
+ 10[V] RPM
Unit
rpm
Display range
0.0 ~ 9999.9
Manufactured
default
Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the +10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-15)
Voltage
P03-16*
-10[V] RPM
Unit
rpm
Display range
-9999.9 ~ 0.0
Manufactured
default
-Applied motor
rated speed
Speed/Torque
control
This sets the command speed range of the -10[V] analog voltage when the servo drive is in
speed control or torque control mode.
Set speed
(P03-16)
Voltage

Other manuals for Higen FDA7030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Higen FDA7030 and is the answer not in the manual?

Higen FDA7030 Specifications

General IconGeneral
BrandHigen
ModelFDA7030
CategoryServo Drives
LanguageEnglish

Related product manuals