2. Wiring and connection
2-4
2.1.2. Connection of AC380V Series
Use within the power specification allowed by the servo. If the power voltage is higher
than the allowable value, be sure to use a power transformer.
FDA7000-H0 : AC 380V, FDA7000-H1 : AC 440V
Use the brake power supply independently. When used with input / output contact input
power, it causes malfunction of contact operation.
To prevent electric shock and suppress noise, ground the motor and drive terminals
with the 3rd or more types of ground at the shortest distance.