10.3.6 Set Object Removal Detecon
It detects whether the objects are removed from the predened detecon region, such as the
exhibits on display. If it occurs, the device can take linkage
acons and the sta can take measures
to reduce property loss.
Before You Start
Go to VCA and select the
applicaon. Select Smart Event and click Next to enable the funcon.
For the device
supporng HEOP, go to VCA to import and enable Smart Event.
Steps
1.
Go to VCA → Set Applicaon → Smart Event → Object Removal Detecon .
2.
Check Enable.
3.
Click Add to add a rule and set a
detecon area.
1) Draw a detecon area. Click , click on the live view to specify the vertexes and draw the
boundaries of the
detecon area, and right click to complete drawing.
2) Set the minimum size and the maximum size for the target to improve detecon accuracy.
Only targets whose size are between the maximum size and the minimum size trigger the
detecon. Click and , then drag the mouse in the live view to draw the minimum and
maximum target size.
3)
Oponal: Click to delete all the seng areas.
4.
Set parameters.
Sensivity
Sensivity stands for the percentage of the body part of an acceptable target that enters the
predened region. Sensivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predened region. ST stands for the complete target body. The higher the value of
sensivity is, the more easily the alarm can be triggered.
Threshold
The threshold for the
me of the objects removed from the region. If you set the value as 10,
alarm is triggered aer the object disappears from the region for 10s.