• Time Threshold
denes the me of the vehicle parking in the region. If you set the value
as 10, alarm is triggered aer the vehicle stay in the region for 10s.
• Sensivity:The size of the object that can trigger the alarm. The higher the value is, the
more easily the detecon alarm will be triggered. Its range is [1-100].
3) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes
of the
detecon region.
6. Set the arming schedule.
7. Set the linkage
acons.
8. Click Apply.
Object Removal Detecon
Object removal detecon funcon detects the objects removed from the pre-dened region, such
as the exhibits on display, and a series of acons can be taken when the alarm is triggered.
Steps
1. Go to
Conguraon → Event → Smart Event → Object Removal .
2. Select Camera to congure.
3. Check Enable Object Removal Detecon.
4. Check Save VCA Picture to save the captured pictures of VCA
detecon.
5. Set the detecon rules and detecon areas.
1) Select Arming Area. Up to 4 arming areas are selectable.
2) Set
Sensivity and Time Threshold.
• Time Threshold range: [5s-3600s]. It
denes the me of the objects removed from the
region. If you set the value as 10, alarm is triggered aer the object disappears from the
region for 10s.
•
Sensivitydenes the similarity degree of the background image. Usually, when the
sensivity is high, a very small object taken from the region can trigger the alarm.
3) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes
of the
detecon region.
6. Set the arming schedule.
7. Set the linkage
acons.
8. Click Apply.
Audio
Excepon
Enter a short descripon of your task here (oponal).
Before You Start
Enter the prerequisites here (oponal).
Enter the context of your task here (oponal).
Steps
1. Enter your
rst step here.
Digital Video Recorder User Manual