10.4 Managing HDD Group
10.4.1 Setting HDD Groups
Purpose:
Multiple HDDs can be managed in groups. Video from specified channels can be recorded onto a particular HDD
group through HDD settings.
Steps:
1. Enter the Storage Mode interface.
Menu > HDD > Advanced
2. Set the Mode to Group, as shown in Figure 10. 13.
Figure 10. 13 Storage Mode Interface
3. Click the Apply button and the following Attention box will pop up.
Figure 10. 14 Attention for Reboot
4. Click the Yes button to reboot the device to activate the changes.
5. After reboot of device, enter the HDD Information interface.
Menu > HDD > General
6. Select HDD from the list and click the icon to enter the Local HDD Settings interface, as shown in
Figure 10. 15.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7104HGHI-SH and is the answer not in the manual?

HIKVISION DS-7104HGHI-SH Specifications

General IconGeneral
Voltage12 V
CertificationCE
Product colorWhite
LED indicatorsYes
Channels quantity4 channels
Maximum frame rate30 fps
Audio output channels2.0 channels
Audio formats supportedG.711
Network connection typeRJ-45
Maximum video resolution1920 x 1080 pixels
Video compression formatsH.264
Playback resolutions supported1920 x 1080, 1280 x 1024, 1280 x 720, 1024 x 768
Video inBNC
Video outHDMI, VGA
Audio input1x RCA
BNC input ports4
USB 2.0 ports quantity2
Number of users128 user(s)
Ethernet interface typeFast Ethernet
Supported network protocolsTCP/IP, PPPoE, DHCP, Hik Cloud P2P, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP, HTTPS
HDD interfaceSerial ATA
Maximum HDD capacity4000 GB
Power requirementsDC
Power consumption (typical)15 W
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Weight800 g
Dimensions (WxDxH)200 x 200 x 45 mm