English 5
Use auxiliary handles, if supplied with the tool. Loss of control can
cause personal injury.
Hold power tool by insulated gripping surfaces, when performing an
operation where the cutting accessory may contact hidden wiring
or its own cord. Cutting accessory contacting a "live" wire may make
exposed metal parts of the power tool "live" and could give the operator
an electric shock.
2.3 Additional safety instructions for rotary hammer
Personal safety
Use the product only when it is in technically faultless condition.
Never tamper with or modify the power tool in any way.
Use the auxiliary grips supplied with the tool. Loss of control can cause
personal injury.
Apply appropriate safety measures at the opposite side of the workpiece
in work that involves breaking through. Parts breaking away could fall out
and / or fall down causing injury to other persons.
Always hold the power tool with both hands on the grips provided. Keep
the grips clean and dry.
Hold the power tool by the insulated gripping surfaces when performing
work in which the accessory tool might come into contact with concealed
wiring. If the accessory tool comes into contact with a live wire, metal
parts of the power tool can also become live, resulting in an electric
shock.
Avoid touching rotating parts risk of injury!
Wear suitable protective glasses, a hard hat, ear defenders, protective
gloves and light respiratory protection while using the power tool.
Wear protective gloves also when changing the accessory tool. Touching
the accessory tool presents a risk of injury (cuts or burns).
Wear eye protection. Flying fragments present a risk of injury to the body
and eyes.
Before starting work, check the hazard class of the dust that will be pro-
duced when working. Use an industrial vacuum cleaner with an officially
approved protection class in compliance with the locally applicable dust
protection regulations. Dust from materials such as lead-based paint,
certain types of wood and concrete/masonry/stone containing quartz,
minerals or metal can be harmful to health.
Make sure that the workplace is well ventilated and, where necessary,
wear a respirator appropriate for the type of dust generated. Contact with
or inhalation of the dust can cause allergic reactions and/or respiratory
or other diseases to the operator or bystanders. Certain kinds of dust
such as oakwood and beechwood dust are classified as carcinogenic,
especially in conjunction with additives for wood conditioning (chromate,
Printed: 02.02.2017 | Doc-Nr: PUB / 5150793 / 000 / 01

Table of Contents

Other manuals for Hilti TE 70-AVR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti TE 70-AVR and is the answer not in the manual?

Hilti TE 70-AVR Specifications

General IconGeneral
CategoryPower Tool
TypeRotary Hammer
Single Impact Energy11.5 J
Hammer Drilling Diameter Range12 - 40 mm
Drilling Diameter Range (Hammer Drill Bits)12 - 40 mm
Dust Removal Module AvailableYes
Power SourceCorded Electric
Voltage230 V
Drilling ModeHammer drilling, chiseling
Vibration ReductionActive Vibration Reduction (AVR)
Drilling Diameter Range (Hollow Drill Bits)40 - 100 mm
Full Hammering Frequency3510 impacts/minute
Blows Per Minute2760 BPM
Sound Pressure Level91 dB(A)
Tool Chuck TypeSDS-max
Tool HolderSDS-max
Vibration Level9.6 m/s² (Hammer drilling into concrete)