(APPENDIX I) PARAMETERS TABLE | PAGE 73
Parameter PSW Description Default value Range
7 2
Change speed limiter
(only control unit with J1939
option)
0
0-Disabled
1..250 Maximum speed
change threshold
(rpm/250ms)
8 2 Idling start-up speed 0 0..1000 rpm
Tabla 15
Screen Table
Parameter PSW Description Default value Range
1 3 Inhibition of buzzer 0
0: Buzzer enabled
1: Buzzer disabled
2 3
PD inhibition in inputs/outputs
menu
0
0: Enable PD activation in
I/O menu
1: Disable PD activation in
I/O menu
3 -
Enabling heating of display
(read-only parameter version DGT
version 4.45 or higher)
-
0: Disabled heating of display
1: Enabled heating of display
4 - Reserved -
5 - Reserved -
6 3 Mode motorpump
0: Motorpump inhibited
1: Motorpump enabled
7 - Unit contactor switch 0
0: Interface without button
1: Interface with button
8 - Reserved -
9 3 Heater integral coefcient
1
5 0..255
10 3 Heater proportional coefcient
1
15 0..255
11 2 Heater target temperature
1
5 0..10
12 2 Contrast
1
5 0..255
1: Version 5.00 or later
Tabla 14
Table J1939
Parameter PSW Description Default value Range
1 3 Engine model 0
SCANIA EMS
VOLVO EDC4
VOLVO EMS2
VOLVO EMS1
IVECO CURSOR
IVECO NEF
JOHN DEERE
MTU (SmartConnect)
PSI
TEDOM
MTU SAM
IVECO CURSOR TIER3
BAUDOUIN
IVECO STAGE V
YANMAR FT4
2 3
Control version
(only expansion CCJ1939)
0
SCANIA (read only.):
160- Control version
161- Control version
REST: not available
3 3 Engine speed 0
Extension CCJ1939:
SCANIA:
0.1: 1500 rpm
2: 1800 rpm
3: idling speed
VOLVO:
Any writing switches speed
between 1500 and 1800
rpm.
IVECO:
0: 1000 rpm
1: 1500 rpm
2: 1800 rpm
Option J1939:
0.1: 1500 rpm
2: 1800 rpm
3: idling speed
4 2 Fine adjustment of speed 125
Fine adjustment of engine
speed
5 3
Speed regulation by analogue
input
0
0: Regulation disabled
1: Regulation enabled
2: Mode CiU (only J1939
option)
6 3 Droop Value 0
Droop Value:
0 - Droop Not enabled
1..250- Droop Value (0.1%)