5
Note: The loading process started by DHCP/BOOTP (see on page 40 "Sys-
tem configuration via BOOTP") shows the selection of "from URL & save lo-
cally" in the "Load" frame. If you get an error message when saving a
configuration, this could be due to an active loading process. DHCP/BOOTP
only finishes a loading process when a valid configuration has been loaded.
If DHCP/BOOTP does not find a valid configuration, then finish the loading
process by loading the local configuration in the "Load" frame.
Figure 17: Load/store dialog
enable Switch to the Priviledged EXEC mode.
copy tftp://149.218.112.159/
switch/config.dat
nvram:startup-config
The Switch loads the configuration data from a
tftp server in the connected network.