Item Specification
2
The port can be changed to long wavelength by replacing the SFP tr
ansceiver of the
bre port on the CHB to the DKC-F810I-1PL8.
3
The port can be changed to long wavelength by replacing the SFP transceiver of the
bre port on the CHB to the DK
C-F810I-1PL16.
4
Measurement Condition: The point 1 m far from oor and surface of the product.
5
Even if storage system is in a power-o state, the cooling fan continues to rotate in a
standby mode.
6
For VSP F1500 with FMDs installed, a minimum of 8 FMDs (min. capacity of 49 TB) are
required for this specic conguration.
7
Does not include the spare drive.
Table 31 Drive specications and guidelines
Type Size (inches)
1
Capacity Speed (RPM)
Transfer rate
(Gbps)
HDD (SAS) 3.5 4.0 TB, 6.0 TB
6
7,200 -
600 GB 10,000 -
2.5 300 GB, 600 GB 15,000 -
2.5 600 GB, 900 GB, 1.2 TB,
1.8 TB
, 2.4 TB
10,000 -
SSD
(MLC SAS) 2
2.5 400 GB
, 800 GB
, 960
GB
, 1.9 TB, 3.8 TB
- 6
3.5 400 GB - 6
Flash Module
(MLC)
- 1.75 TB, 3.5 TB, 7 TB, 14
TB
- 6
Drive installation guidelines
■
A minimum of 4 drives must be installed for VSP G1x00. For VSP F1500, a minimum of 8 drives
must be installed.
■
Drives must be added in groups of 4, 8, or 16 when cr
eating RAID groups, unless they are spare
drives.
Appendix A: Storage system specications
Hitachi Virtual Storage Platform G1000, G1500, and VSP F1500 Hardware Guide 136