Deskstar 7K500 and Deskstar E7K500 Hard Disk Drive Specification
193
12.38.3 Set Max Unlock (Feature = 03h)
Table 144: Set Max Unlock command (F9h)
If this command is immediately preceded by a Read Native Max Address command, the device regards it as Set
Max Address command
This command requests a transfer of a single sector of data from the host including the information specified in
Table 141: “Set Max Set Password command” on page 191 with the stored SET MAX password.
If the password compare fails, the device returns an abort error to the host and decrements the unlock attempt
counter. This counter is initially set to 5 and is decremented for each password mismatch. When this counter
reaches zero, all Set Max Unlock commands are rejected until a hard reset or a power off occurs.
If the password compare matches, the device sets the Set_Max_Unlocked state and all Set Max commands are
accepted.
Command Block Output Registers Command Block Input Registers
Register 7 6 5 4 3 2 1 0 Register 7 6 5 4 3 2 1 0
Data - - - - - - - - Data - - - - - - - -
Feature 0 0 0 0 0 0 1 0 Error see below
Sector Count - - - - - - - - Sector Count - - - - - - - -
Sector Number - - - - - - - - Sector Number - - - - - - - -
Cylinder Low - - - - - - - - Cylinder Low - - - - - - - -
Cylinder High - - - - - - - - Cylinder High - - - - - - - -
Device/Head 1 - 1 D - - - - Device/Head 1 - 1 D - - - -
Command 1 1 1 1 1 0 0 1 Status see below
Error Register Status Register
7654321 0 76543 21 0
CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR
00000V0 0 0V0-- 0- V