EasyManua.ls Logo

Hitachi HDS725050KLA360 - Set Max Freeze Lock (Feature = 04 H)

Hitachi HDS725050KLA360
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deskstar 7K500 and Deskstar E7K500 Hard Disk Drive Specification
194
12.38.4 Set Max Freeze Lock (Feature = 04h)
Table 145: Set Max Freeze Lock (F9h)
If the Set Max Freeze Lock command is immediately preceded by a Read Native Max Address command, this
command is regarded as a Set Max Address command.
The Set Max Freeze Lock command sets the device to Set_Max_Frozen state. After the completion of the com-
mand any subsequent Set Max commands are rejected. The following commands are disabled by Set Max Freeze
Lock:
Set Max Address
Set Max Set PASSWORD
•Set Max Lock
Set Max Unlock
Command Block Output Registers Command Block Input Registers
Register 7 6 5 4 3 2 1 0 Register 7 6 5 4 3 2 1 0
Data - - - - - - - - Data - - - - - - - -
Feature 0 0 0 0 0 0 1 0 Error see below
Sector Count - - - - - - - - Sector Count - - - - - - - -
Sector Number - - - - - - - - Sector Number - - - - - - - -
Cylinder Low - - - - - - - - Cylinder Low - - - - - - - -
Cylinder High - - - - - - - - Cylinder High - - - - - - - -
Device/Head 1 - 1 D - - - - Device/Head 1 - 1 D - - - -
Command 1 1 1 1 1 0 0 1 Status see below
Error Register Status Register
7654321 0 76543 21 0
CRC UNC 0 IDN 0 ABT T0N AMN BSY RDY DF DSC DRQ COR IDX ERR
00000V0 0 0V0-- 0- V

Table of Contents