12-15
Display
(Function mode 1) (Function mode 2)
Setting, change
sequence
Function Function Initialization display Initialization
contents
Setting contents
No. name contents
38 F-47 Main body OP-ERR1 STP STP STP/RUN Effective with option board
Option operation
PCB error selection for
setting option PCB
error 1
Main body OP-ERR2 STP STP STP/RUN
operation
selection for
option PCB
error 2
39 F-48 Setting for RELAY RYA RUN RUN CST/PAT Effective with option board
Selection RYA /ANY/RUN (J-RY)
of relay terminal /OTQ/NOR
output Setting for RELAY RYB CST CST CST: Arrival signal
RYB (constant speed)
terminal PAT: Arrival signal
Setting for RELAY RYC OTQ OTQ (set frequency or more)
RYC ANY: Arrival signal
terminal (set frequency only)
RUN: Running signal
OTQ: Over torque signal at
SLV, SLV2/Overload
signal at V/F control
NOR: No output