EasyManua.ls Logo

Hitachi L700 Series - Page 191

Hitachi L700 Series
263 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Explanation of Functions
4 - 129
(iii) List of registers (monitoring)
Register
No.
Function name Function code R/W Monitoring and setting items
Data
resolution
1001h
Output frequency monitoring
d001 (high)
R 0 to 40000 0.01 [Hz]
1002h d001 (low)
1003h Output current monitoring d002 R 0 to 9999 0.1 [A]
1004h Rotation direction minitoring d003 R
0: Stopping, 1: Forward rotation, 2: Reverse
rotation
0.1 [Hz]
1005h
Process variable (PV), PID
feedback monitoring
d004 (high)
R 0 to 9990 0.1
1006h d004 (low)
1007h Intelligent input terminal status d005 R 2^0: Terminal 1 to 2^7: Terminal 8 1 bit
1008h
Intelligent output terminal
status
d006 R 2^0: Terminal 11 to 2^4: Terminal 15 1 bit
1009h
Scaled output frequency
monitoring
d007 (high)
R 0 to 39960 0.01
100Ah d007 (low)
100Bh
Actual-frequency monitoring
d008 (high) R
-40000 to +40000 0.01 [Hz]
100Ch d008 (low) R
100Dh Torque command monitoring d009 R -200 to +200 1 [%]
100Eh Torque bias monitoring d010 R -200 to +200 1 [%]
100Fh (Reserved) - - Inaccessible -
1010h Torque monitoring d012 R -200 to +200 1 [%]
1011h Output voltage monitoring d013 R 0 to 6000 0.1 [V]
1012h Power monitoring d014 R 0 to 9999 0.1 [kW]
1013h
Cumulative power monitoring
d015 (high)
R 0 to 9999999 0.1
1014h d015 (low)
1015h
Cumulative operation RUN
time monitoring
d016 (high)
R 0 to 999900 0.1
1016h d016 (low)
1017h
Cumulative power-on time
monitoring
d017 (high)
R 0 to 999900 1 [h]
1018h d017 (low)
1019h
Heat sink temperature
monitoring
d018 R -200 to 2000 0.1 []
101Ah Motor temperature monitoring d019 R -200 to 2000 0.1 []
101Bh
(Reserved) - - Inaccessible -
101Ch
101Dh Life-check monitoring d022 R
2^0: Capacitor on main circuit board
2^1: Low cooling-fan speed
1 bit
101Eh to
1025h
(Reserved) - - Inaccessible -
1026h
DC voltage monitoring (across
P and N)
d102 R 0 to 9999 0.1 [V]
1027h BRD load factor monitoring d103 R 0 to 1000 0.1 [%]
1028h
Electronic thermal overload
monitoring
d104 R 0 to 1000 0.1 [%]
1029h to
102Dh
(reserved) - - Inaccessible -
102Eh
User monitor 1
d025(HIGH) R
-2147483647 to 2147483647 1
102Fh d025(LOW) R
1030h
User monitor 1
d026(HIGH) R
-2147483647 to 2147483647 1
1031h d026(LOW) R
1032h
User monitor 1
d027(HIGH) R
-2147483647 to 2147483647 1
1033h d027(LOW) R
1034h
Pulse counter
d028(HIGH) R/W
0 to 2147483647 1
1035h d028(LOW) R/W
1036h
Position setting monitor
d029(HIGH) R
-2147483647 to 2147483647 1
1037h d029(LOW) R
1038h
Position feedback monitor
d030(HIGH) R
-2147483647 to 2147483647 1
1039h d030(LOW) R
103Ah to
1102h
Unused - Inaccessible -
(iv) List of registers
Register
No.
Function name Function code R/W Monitoring and setting items
Data
resolution
1103h
Acceleration (1) time setting
F002 (high)
R/W 1 to 360000 0.01 [sec.]
1104h F002 (low)
1105h
Deceleration (1) time setting
F003 (high)
R/W 1 to 360000 0.01 [sec.]
1106h F003 (low)
1107h Keypad Run key routing F004 R/W 0 (forward rotation), 1 (reverse rotation) -
1108h to
1200h
Unused - - Inaccessible -

Table of Contents