CAPACITIES AND SELECTION DATA
3-37
3.5.3.
RAM-53NE3F
Whichever indoor units are installed, cooling and heating capacity depends on how many and which indoor units are operating at
the same time.
[1] Capacity loss due to white frost and defrost operation is not included.
POSSIBLE
COMBINATIONS
TO OPERATE
COOLING HEATING
TOTAL
(kW)
CAPACITY
RATING(kW) (RANGE)
OUTDOOR UNIT
EER
CAPACITY
RATING(kW)
(RANGE)
OUTDOOR UNIT
COP
TOTAL
INPUT
(W)
AMPERE(A)
TOTAL
INPUT
(W)
AMPERE(A)
TOTAL
220V
230V
TOTAL
[1]
220V
230V
ONE UNIT
1.5 1.5 1.50 1.50 700 3.2
3.1
2.9
2.00 2.00 850 3.9 3.7 3.6
2.35
(1.00-1.60) (350-800)
(1.50-2.20) (700-1100)
1.8 1.8 1.80 1.80 730 3.4
3.2
3.1
2.50 2.50 900 4.1 4.0 3.8
2.78
(1.50-2.00) (350-800)
(1.80-3.50) (700-1200)
2.5 2.5 2.50 2.50 800 3.7
3.5
3.4
3.40 3.40 1000 4.6 4.4 4.2
3.40
(1.50-2.80) (350-900)
(1.80-4.70) (700-1500)
3.5 3.5 3.50 3.50 1030 4.7
4.5
4.3
4.30 4.30 1300 6.0 5.7 5.5
3.31
(1.50-3.90) (350-1200)
(1.80-5.80) (700-1800)
5.0 5.0 5.00 5.00 1300 6.0
5.7
5.5
5.80 5.80 1700 7.8 7.5 7.2
3.41
(1.50-5.60) (350-1700)
(1.80-6.60) (700-1800)
TWO UNITS
1.5+1.5 3.0 1.50+1.50 3.00 900 4.1
4.0
3.8
2.00+2.00 4.00 1080 5.0 4.7 4.5
3.70
(1.50-3.50) (500-1100)
(2.20-4.70) (800-1400)
1.5+1.8 3.3 1.50+1.80 3.30 930 4.3
4.1
3.9
2.00+2.50 4.50 1300 6.0 5.7 5.5
3.46
(1.50-3.50) (500-1130)
(2.20-5.20) (800-1600)
1.5+2.5 4.0 1.50+2.50 4.00 1000 4.6
4.4
4.2
2.00+3.40 5.40 1500 6.9 6.6 6.3
3.60
(1.50-4.00) (500-1300)
(2.20-6.40) (800-1500)
1.5+3.5 5.0 1.50+3.50 5.00 1100 5.1
4.8
4.6
2.00+4.30 6.30 1600 7.3 7.0 6.7
3.94
(1.50-5.20) (500-1710)
(2.20-6.60) (800-2250)
1.5+5.0 6.5 1.22+4.08 5.30 1200 5.5
5.3
5.1
1.48+4.82 6.30
1880
8.6 8.3 7.9
3.35
(1.50-6.00) (500-1710)
(2.20-6.60) (800-2250)
1.8+1.8 3.6 1.80+1.80 3.60 1300 6.0
5.7
5.5
2.50+2.50 5.00 1450 6.7 6.4 6.1
3.45
(1.50-5.90) (500-1150)
(2.20-6.40) (800-2000)
1.8+2.5 4.3 1.80+2.50 4.30 1300 6.0
5.7
5.5
2.50+3.40 5.90 1500 6.9 6.6
6.3
3.93
(1.50-5.90) (500-1550)
(2.20-6.60) (800-2250)
1.8+3.5 5.3 1.80+3.50 5.30 1350 6.2
5.9
5.7
2.32+3.98 6.30 1620 7.4 7.1
6.8
3.89
(1.50-5.90) (500-1710)
(2.20-6.60) (800-2250)
1.8+5.0 6.8 1.40+3.90 5.30 1450 6.7
6.4
6.1
1.75+4.55 6.30 1800 8.3 7.9
7.6
3.50
(1.50-5.90) (500-1710)
(2.20-6.60) (800-2250)
2.5+2.5 5.0 2.50+2.50 5.00 1500 6.9
6.6
6.3
3.15+3.15 6.30
1600
7.3 7.0
6.7
3.94
(2.00-5.50) (500-1710)
(2.20-6.60) (800-2250)
2.5+3.5 6.0 2.21+3.09 5.30 1550 7.1
6.8
6.5
2.78+3.52 6.30
1880
8.6 8.3
7.9
3.35
(2.00-6.00) (500-1710)
(2.20-6.60) (800-2250)
2.5+5.0 7.5 1.77+3.53 5.30 1600 7.3
7.0
6.7
2.16+4.14 6.30
1880
8.6 8.3
7.9
3.35
(2.00-6.00) (500-1710)
(2.20-6.60) (800-2250)
3.5+3.5 7.0 2.65+2.65 5.30 1600 7.3
7.0
6.7
3.15+3.15 6.30
1880
8.6 8.3
7.9
3.35
(2.00-6.00) (500-1710)
(2.20-6.60) (800-2250)
3.5+5.0 8.5 2.18+3.12 5.30 1600 7.3
7.0
6.7
2.51+3.79 6.30
1880
8.6 8.3
7.9
3.35
(2.00-6.00) (500-1710)
(2.20-6.60) (800-2250)