WORKING RANGE
5-2
5.1. POWER SUPPLY
Working Voltage 198V ~ 264V
Voltage Imbalance
Within a 3% Deviation from Each Voltage at the Main Terminal of
Outdoor Unit
Starting Voltage Higher than 85% of the Rated Voltage
5.2. WORKING RANGE
5.2.1. MULTIZONE
Applicable models:
MULTIZONE
RAM-40NE2F
RAM-53NE2F
RAM-53NE3F
The temperature range is indicated in the following table.
Cooling
Heating
working range min (
o
C) max (
o
C) rated (
o
C) working range
min (
o
C) max (
o
C) rated (
o
C)
outdoor -10 46 35 outdoor -15 24 7
indoor 16 32 27 indoor 16 27 20
-20
-10
0
10
20
30
40
50
-10 -5 0 5 10 15 20 25 30 35 40
Ambient temperature
Indoor temperature
Cooling working range
-20
-10
0
10
20
30
40
50
-10 -5 0 5 10 15 20 25 30 35 40
Ambient temperature
Indoor temperature
Heating working range
Indoor Temperature
Indoor Temperature
Ambient Temperature
Ambient Temperature
COOLING
HEATING