Suction ends in about 1 minute and the screen returns to the Circulation 
control screen.
 ● To stop operation, press  Abort .
4
Check if ink stream bending or nozzle clogging has been repaired.
 ● Display the screen after the Circulation control screen.
5
With the print head cover removed, press the  Ink stream alignment →
 Start/Continue  to eject the makeup.
 ● Perform this work with the print head tip inserted into a beaker.
6
Confirm that the stream is in the center of the gutter.
 ● Confirm the stream position from the horizontal direction and vertical direction of the print head 
as shown in the figure.
7
 ● If the ink stream is not in the center of the gutter, perform nozzle backwash again.
      If the stream is not corrected even after the nozzle backwash has been performed 3 times, 
      perform par. “6.4.2 Nozzle orifice disassembly and cleaning”.
At the end of confirmation, press  Abort  and stop ejection of the makeup.
8