5-29 Transmission Sequences
5.3.8 On-line/off-line Transmission Procedure
5.3.8-1 Text
(1) Change to online
ESC2 Header 73H
(2) Change to offline
ESC2 Header 74H
ESC Header 79H
(1) Change to online
(2) Change to offline
ESC Header 7AH
In the following cases, Online/Offline transmission cannot be performed.
If it is attempted, NAK code will be the reply:
"Apply" key is displayed while inputting set value.
In the "Communication environment setup" screen, "Off fixed" is selected for "State at power-up"
item.
During input of count conditions.
The confirmation window is open.
The circulation control screen is opened by the maintenance function.
The touch screen setup screen is opened by the auxiliary function.
The communication monitor screen is opened.
2
1
3
4
5
6
5.3.8-2 Transmission example
ESC2 73H
ACK
External device
IJ printer
7
[Existing machine message] Existing machine message can also be used.
ENQ, STX and ETX are not required.