5-13 Transmission Sequences
(3)Print format text
Line count and Line spacing
ESC2 Header 22H
Classification
32H
Line count Line spacing
Line count (1 to 5)
Line spacing (0 to 2)
Character size and inter-character space
ESC2 Header 23H
Classification
31H
Character size 10s place Units place
Increased width
ESC2 Header 23H
Classification
32H
Increased
width
Increased width (1 to 9)
Bar code type (Type change, Bar code "not used" "used")
ESC2 Header 23H
Classification
33H
Type
Bar code type (30H to 46H)
Bar code "used" "not used"
ESC2 Header 23H
Classification
33H
30H
30H :Bar code "not used"
Readable code (Bar code EAN-13)
ESC2 Header 23H
Classification
34H
Code
Prefix code (Bar code EAN-13)
ESC2 Header 23H
Classification
35H
Tens position Units position
Prefix code (00 to 99)
Two or more print format items can be consecutively transmitted in a single chain.
Inter-character space (0 to 28)
Character size
(30H to 3CH)
Bar code type
30H : not used
31H : code 39
32H : ITF
33H : NW-7
34H : EAN-13
35H : DM8x32
36H : DM16x16
37H : DM16x36
38H : DM16x48
39H : DM18x18
3AH: DM20x20
3BH: DM22x22
3CH: DM24x24
3DH: Code 128 (Code set B)
3EH: Code 128 (Code set C)
3FH: UPC-A
40H: UPC-E
41H: EAN-8
42H: QR21x21
43H: QR25x25
44H: QR29x29
45H: GS1 DataBar (Limited)
46H: GS1 DataBar
(Omnidirectional)
Readable code type (0: None, 1: 5 x 5, 2: 5 x 7)
Character size
30H : 4x5
31H : 5x5
32H : 5x8(5x7)
33H : 9x8(9x7)
34H : 7x10
35H : 10x12
36H : 12x16
37H : 18x24
38H : 24x32
39H : 11x11
3AH: 5x3(Chimney)
3BH: 5x5(Chimney)
3CH: 7x5(Chimney)