Communication Timing 5-48
No. Transmission type Conditions
T2 Minimum time (ms)
Remarks
Within 24 items 25 items or more
1 Print description
The print message transfer
ACK condition is t=fixed.
(M: Number of
communication
characters)
(M: Number of
communication
characters)
*6 *9
The print message transfer
ACK condition is t=async.
00
2 Print data recall
When the character height, character
width, character orientation, ink drop
use percentage, or print format changes
before or after recall
400 400 *7
When the character height,
character width, character orientation,
ink drop use percentage, or print format
does not change before or after recall
40 40 *8
3
Print data
registration
-3030
4
Print conditions
Print specifications 400 400 *7
5 Print format 400 400 *7
6 Overall column setup 200 200 *8
7
User pattern
character
-2525
8 Date/time setup -
(M: Number of
printing
characters)
(M: Number of
printing
characters)
*6
External
device
IJprinter
ETX
ACK
STX
ENQ
ACK
5ms(*5)
T2
Printing
operation
Printstartsignal
(2) Time interval (T2) between IJ printer response and printing start
The IJ printer executes an internal process to make printing preparations in accordance with the received print
data. Do not enter the print start signal during internal process execution.
In the overwrite-protected mode, initiate the next communication after completion of printing.
In the overwrite-enabled mode, the next communication can be transmitted during printing, but the ACK/
NAK response does not return until the ongoing printing operation is complete. (t=async.)
When a print start signal is input with shorter timing than T2, the fault "Print data changeover in progress M"
occurs.
The more different items of the print format, the longer the time until ready to print.
*5 If the communication time interval is not sufficiently secured, it may not operate normally.
*6 When there is a data matrix and QR code setting, the time is as follows:
*7 When there is a QR code setting, T2 Minimum time is 400xN (ms) (N : Number of QR codes).
*8 When there is a QR code setting, the time is as follows:
M
10
+15
M
10
+30
M
10
+15
M
10
+45
Time T2 when there is a data matrix and QR code setting
Character size
T2 Minimum time (ms)
Within 24 items 25 items or more
Data matrix
5x8 8x N+20 100
12x16, 18x24 15x N+40 150
QR code
QR (21x21) 200xN 200xN
QR (25x25) 300xN 300xN
QR (29x29) 400xN 400xN
(N : Number of 2-Dimensional codes)