Warning Messages 5-52
Error
code
Name Description Check
014 Parity error The parity error occurred. Check the baud rate and data format.
015
Print format code
error
The print format data value was illegal.
Check the print format transmission text
section.
016 Overrun error The overrun error occurred. Check the baud rate and data format.
017 Framing error The framing error occurred. Check the baud rate and data format.
019 2-byte code error
An illegal 2-byte code (2 bytes per
character) was transmitted.
Only one byte of 2-byte code was
transmitted.
Check the 2-byte code transmission text.
020 Print data code error
The print data registration number was
illegal.
An unregistered number was
encountered.
Check the print data recall / transmission
code.
021 SI/SO code error
The SI (shift in) or SO (shift out) code
position was illegal.
Check the printings communication text.
022
User pattern
character size/
character code error
The character size or character code
values were illegal.
Check the user pattern communication
text.
023
High-speed
printing setup error
When necessary conditions for high
speed printing were not satisfied, NM
or QM mode was transmitted.
When High speed printing NM or QM
mode was set, a setting which did not
satisfy necessary conditions for high
speed printing was transmitted.
Check the print specifications
communication text.
024
Calendar/count
conditions error
Transmitted to block where
calendar/count characters were not
present.
Set value was outside specifications.
Zero suppression transmission was
performed to print item for which
barcode had been set.
Check calendar/count condition
communication text.
026 Bar code setup error
A character undefined for bar code use
was found in the printings.
The number for ITF did not consist of
an even number of numerals
beginning with an odd digit position.
The input data for EAN-13 was not
numeric.
Check the printings print format
communication text.
027 Printings error
A dedicated character or katakana was
transmitted in a character size which
cannot be inputted.
The three characters of a dedicated
character string were not properly
grouped.
A count value is out of a count range.
Check the printings communication text
031
Create messages
error
While "Create messages" function was
operating, on-line transmission was
performed.
On-line transmission was performed
when print data which was controlled
separately from data created and
registered by print description screen,
was present.
Check the timing of on-line
transmission.
032
Setting conditions
error
Setting value does not satisfy the
required conditions.
Communication text re-check.
033 Setting range error Setting value is out of stipulated range. Communication text re-check.