EasyManuals Logo

Hitachi Universal Storage Platform V Configuration Guide

Hitachi Universal Storage Platform V
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Installing the USP V 2-7
Hitachi Universal Storage Platform V/VM Configuration Guide for SGI
®
IRIX
®
Host Attachment
Setting the Host Mode Options
When each new host group is added, the storage administrator must be sure
that all host mode options are set for all host groups connected to SGI IRIX
SGI IRIX hosts.
Select the common host mode option 13 when the conditions in
Table 2-2 are met.
WARNING: Changing host mode options on USP V systems that are already
installed and configured is disruptive and requires the server to be rebooted.
Table 2-2 Common Host Mode Options for the USP V
No. Host Mode
Option
Select if the Following Conditions are Met Remarks
13
SIM report at
link failure
SIM notification is required when the number of link failures
detected between ports exceeds the threshold.
Optional
You can use either the LUN Manager software (Storage Navigator) or the
HiCommand
®
Device Manager software to set the host mode options. For more
information about using LUN Manager, see the Hitachi Universal Storage
Platform V LUN Manager User’s Guide (MK-96RD615).

Other manuals for Hitachi Universal Storage Platform V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Universal Storage Platform V and is the answer not in the manual?

Hitachi Universal Storage Platform V Specifications

General IconGeneral
BrandHitachi
ModelUniversal Storage Platform V
CategoryStorage
LanguageEnglish

Related product manuals