24
Holding register data configuration (10/13)
Word
address
Classification Item name Setting range Contents
25 80
Touch screen
setup
Display 0 to 2
Sets the display.
0:OFF in 3 min. , 1:OFF in 30 min.
2:Always ON
25 81 Keyboard layout 0 , 1
Sets the keyboard layout.
0:ABC , 1:QWERTY
25 82 ICON Display 0 , 1
Sets the ICON display.
0:Disable , 1:Enable
25 83 Clock display format 0 to 2
Sets the clock display format.
0:YYYY.MM.DD , 1:DD.MM.YYYY
2:MM.DD.YYYY
25 84
Confirmation window for
Manual Control Menu
0 , 1
Sets the confirmation window for
manual control menu.
0:Display , 1:Non display
25 85 Arabic input method 0 , 1
Sets the Arabic input method.
0:to the left , 1:to the right
25 86 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
… …
25 8F Reserve_10
25 90
Reserve
Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
… …
25 AF Reserve_32
25 B0
Operation
management
Ink operating time 0 to 9999 Sets the ink operating time.
25 B1 Ink alarm time 0 to 9999 Sets the ink alarm time.
25 B2
Print count 0 to 999999999 Sets the print count.
25 B3
25 B4 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
… …
25 B7 Reserve_4
25 B8
Circulation
control
Ink filter use time 0 to 65099 Sets the ink filter use time.
25 B9 Reserve_1 -
"Reserve" is not initially provided,
but may be added in future.
25 BA Recovery filter 1 use time 0 to 65099 Sets the recovery filter 1 use time.
25 BB Air filter use time 0 to 65099 Sets the air filter use time.
25 BC Reserve_1 -
"Reserve" is not initially provided,
but may be added in future.
25 BD Recovery filter 2 use time 0 to 65099 Sets the recovery filter 2 use time.
25 BE Air filter L use time 0 to 65099 Sets the air filter L use time.
25 BF Air filter R use time 0 to 65099 Sets the air filter R use time.
25 C0 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
… …
25 DF Reserve_32