(2) Input Registers
Input Registers are the area read by Read Input Registers (0x04).
The item data is placed, which can be obtained from IJ Printer.
Input Registers can be read by one (1) word (2 bytes) at every address.
Input Register data configuration (1/9)
Word
address
Classification Item name Setting range Contents
00 00
Unit status
Communication connection
status
0x0030 , 0x0031
Gets the communication
connection status.
0x0030:Offline , 0x0031:Online
00 01 Receive enable/disable status 0x0030 , 0x0031
Gets the receive enable/disable
status.
0x0030:Reception not possible
0x0031:Reception possible
00 02 Operation status 0x0000 to 0xFFFF
Gets the operation status.
Status can be obtained by use of
the same code as that of the
Status output of SOP-04 (Special
Communication Function A). Refer
to Software Option Specification
SOP-04 for details.
00 03 Warning status 0x0000 to 0xFFFF
00 04
Analysis information 1
(Function code)
0x0000 to 0xFFFF
Cause will be obtained when the
external communication error
occurred during Modbus
communication. Refer to 4.5 (1)
Details of Analysis information for
details.
Analysis information 1
Function code is obtained when
error is caused.
Analysis information 2
Classification code is obtained
when error is caused.
Analysis information 3
Error factor is obtained when
error is caused.
Analysis information 4
[0x0000] Fixed
00 05
Analysis information 2
(Classification code)
0x0000 to 0xFFFF
00 06
Analysis information 3
(Error factor)
0x0000 to 0xFFFF
00 07
Analysis information 4
(Preparation for future)
0x0000 to 0xFFFF
00 08 Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
00 0F Reserve_8
00 10
Unit
information
Type name(1st digit) 0x0030 to 0x007A
Gets the type name.
Model name UX-D860W is
obtained when it is used.
00 11 Type name(2nd digit) 0x0030 to 0x007A
00 1E Type name(15th digit) 0x0030 to 0x007A
00 1F Type name(16th digit) 0x0030 to 0x007A
00 20
Serial number
00000000 to
99999999
Gets the serial number.
00 21
00 22 Ink name(1st digit) 0x0030 to 0x007A
Gets the ink name.
Ink type 1067K is obtained when it
is used.
00 23 Ink name(2nd digit) 0x0030 to 0x007A
00 2A Ink name(9th digit) 0x0030 to 0x007A
00 2B Ink name(10th digit) 0x0030 to 0x007A