General Software 15 (38)
5.5 Control Register CTRL_AUX-bit
30-series The CTRL_AUX bit in the control register indicates to the Anybus CompactCom if the
process data in the current telegram has changed compared to the previous one.
40-series The value of the CTRL_AUX bit is always ignored. Process data is always accepted.
All released Anybus CompactCom 30 example drivers from HMS comply with this difference.
Related Information: Anybus CompactCom 40 Software Design Guide (HMSI-216-125), section
“Control Register”.
5.6 Status Register STAT_AUX-bit
30-series The STAT_AUX bit in the status register indicates if the output process data in the current
telegram has changed compared to the previous one. This functionality must be enabled
in the Anybus object (01h), Attribute #15. By default, the STAT_AUX bit functionality is
disabled.
40-series The STAT_AUX bit indicates updated output process data (not necessarily changed data)
from the network compared to the previous telegram. The functionality is always enabled.
All released Anybus CompactCom 30 example drivers from HMS comply with this difference.
Related Information: Anybus CompactCom 40 Software Design Guide (HMSI-216-125), section
“Status Register”.
5.7 Control Register CTRL_R-bit
30-series The application may change this bit at any time.
40-series For the 8-bit parallel operating mode, the bit is only allowed to transition from 1 to 0 when
the STAT_M-bit is set in the status register. When using the serial operating modes, it is
also allowed to transition from 1 to 0 in the telegram immediately after the finalizing empty
fragment.
All released CompactCom 30 example drivers from HMS comply with this difference.
Related Information: Anybus CompactCom 40 Software Design Guide (HMSI-216-125), section
“Control Register”.
5.8 Modifications of Status Register, Process Data Read Area,
and Message Data Read Area
In the 40-series, the Status Register, the Process Data Read Area, and the Message Data Read
Area are write protected in hardware (parallel interface). If the software for some reason writes
to any of those areas, a change is needed.
All released Anybus CompactCom 30 example drivers from HMS comply with this difference.
Migrating from Anybus
®
CompactCom
30 to Anybus
®
CompactCom
40 Design Guide SCM-1202-043 1.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HMS Anybus CompactCom 30 and is the answer not in the manual?

HMS Anybus CompactCom 30 Specifications

General IconGeneral
BrandHMS
ModelAnybus CompactCom 30
CategoryControl Unit
LanguageEnglish

Related product manuals