Network Specific PROFINET 28 (38)
13.2 PROFINET IO Object (F6h)
Attribute Default Anybus CompactCom Product Comment
#1, Device
ID
0007h 30-series, PROFINET IO 1-Port The Device ID controls how your
product identifies itself on the PROFI-
NET network.
If the attribute is implemented in the
host application, it overrides the de-
fault value and there is no difference
between the 30-series and the 40-
series.
If the attribute is not implemented,
the default value differs between the
different CompactCom PROFINET
types.
0009h 30-series, PROFINET IO 2-Port
0010h 40-series, PROFINET IRT
#3, Station
Type
“ABCC-PRT” 30-series, PROFINET IO 1-Port The Station Type defines the name
your product uses to identify itself on
the PROFINET network.
If the attribute is implemented in the
host application, it overrides the de-
fault value and there is no difference
between the 30-series and the 40-
series.
If the attribute is not implemented,
the default value differs between the
different CompactCom PROFINET
types.
“ABCC-PRT
(2-Port)”
30-series, PROFINET IO 2-Port
“ABCC40-
PIR”
40-series, PROFINET IRT
#8, I&M Or-
der ID
“ABCC-PRT” 30-series, PROFINET IO 1-Port If the attribute is implemented in the
host application, it overrides the de-
fault value and there is no difference
between the 30-series and the 40-
series.
If the attribute is not implemented,
the default value differs between the
different Anybus CompactCom PRO-
FINET types.
“ABCC-PRT
(2-Port)”
30-series, PROFINET IO 2-Port
“ABCC40-
PIR”
40-series, PROFINET IRT
#19, System
Description
“HMS Indus-
trial Net-
works Any-
bus Com-
pactCom”
30-series, PROFINET IO 1-Port If the attribute is implemented in the
host application, it overrides the de-
fault value and there is no difference
between the 30-series and the 40-
series.
If the attribute is not implemented,
the default value differs between the
different Anybus CompactCom PRO-
FINET types.
“Anybus
Compact-
Com PROFI-
NET IO 2-
Port”
30-series, PROFINET IO 2-Port
“HMS Indus-
trial Net-
works Any-
bus-Com-
pactCom 40”
40-series, PROFINET IRT
Migrating from Anybus
®
CompactCom
30 to Anybus
®
CompactCom
40 Design Guide SCM-1202-043 1.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HMS Anybus CompactCom 30 and is the answer not in the manual?

HMS Anybus CompactCom 30 Specifications

General IconGeneral
BrandHMS
ModelAnybus CompactCom 30
CategoryControl Unit
LanguageEnglish

Related product manuals