OM 2012
NOTE:
if arrtificeze So!lJtiSl is not P’emhd, pour requii:cd antifreeze
in first. hstult corrcsion inhibits cccording to directions on
a container.
(3) Start the er?ginc ynd allow it to idle. Add cooiant if trappd air escapes from
the system and the coziant level falls.
‘(4 c
anti:-iue to check coolant leve! until the engine reaches operating temperature.
Add coolant, if needed, to fili to.the required level, 1 inch below filler neck.
InstaIl radiatti cap.
.
NOlE :
It is good practice to attach a card,
indicating the cooling system
contenb, and the date serviced to the rudiator filter neck.
.
8. Generator biainfenarce
-
.
The 400-Hz generator requires no maintenance or service other than periodic cleaning.
Clean the complete generator set wl~cn other compwxrh of the tow tractor are cleaned.
The unit is brushless, and bearings are permanently lubricated and sealed.
‘A. Cleaning
.
The generator may be cleaned by careful use of compressed air and/or a good,
SAFE commercial cleaner.
Steam cleaning of the generator is no longer recom-
mended because the use of steam and harsh chemical compounds may result in
damage to insulation and other generator components.
CAUTION: BE SURE THE UNIT IS COMPLETELY DRY BEFORE ORRATlNG.
WARNING: DO NOT USE A FLAMMABLE SOLVENT.
9.
Adiustment
The generator itself requires no adjustment.
controls will be covered in Section 2-3.
Adiustment procedures for generator
-u ‘-- --
. 2-1
Aua 25185
Page 18