OM 2012
(5)
(e) Remove oil filler cap (Sect. 1-2, Fig. 1) and refill the crankcase with
new, clean oil which meets engine manufacturer’s recommendations.
(See Para. 4, D, (2) aba
ve, or Detroit Diesel Operator’s Manual.)
Engine oil capacity is as follows:
21-l/2 quarts - including filter.
20 quarts - not including filter.
CAUTION: 1. ALWAYS USE CLEAN CONTAINER, FUNNELS, ETC.
2. DON’T FORGET TO:
- DRAIN OLD OIL.
- RE INSTALL DRAIN PLUG o
- INSTALL MW OIL BEFORE STARTING ENGINE.
(f) lnstaii fiile r cap and check oil level on gage rod (Sect. l-2, Fig. 1).
The gage rod should indicate over FULL until the engine is started and
oil is circulated to fill the oii filter.
(a) Start engine and check oil pressure at once. Normal pressure should be
indicated within 15 seconds. Allow engine to idle for about 5 minutes,
then stop.
.
(h) After the engine has been stopped for about 5 minutes, recheck the oil
level. Add oil, if required, to bring the level up to the FULLmark
onthegagerod.
Change oil filter element
Replacement oil filter elements are available from AC Delco NOTE:
as part nunber 25OTo495.
(a) Provide a container for catching used oil if the vessel used for draining
the crankcase is not sufficiently wide to serve both operations.
(b) Remove drain plug (6, Fig. 7), and allow oil to drain.
(c) loosen center stud (5) and remove stud (5), shell (4), element (3), and
gasket (2) as an assembly.
Discard the gasket and element.
(d) Clean the filter base (1).
(e) Wipe out the interior of the shell (4) with a clean, lint-free cloth.
Aug ~5035
Install a new element (3) on the center stud (5) and in the shell (4).