9.1 Alarming
There are two types of alarm: Immediate alarm and delayed alarm.
When the 24-hour zone is triggered, the alarm immediate triggers. 24-hour zones includes: Fire zone,
Gas zone, Panic zone, Emergency zone and Tamper zone.
24-hour zones will trigger alarm whether the alarm system is activated or not.
If the alarm system is triggered by a sensor with delay, there will be a voice guidance saying "Alarm,
please disarm!" Disarm (disable) before the music stops, then no alarm message will be send. If you
disarm after the music stops, then an alarm message will be send. Entry Delay is only valid for entry/exit
zones and activity zones.
1. Exit/entry zones will only be triggered with delay in "Arm Away" and
"Arm Stay".
2. The activity zone will only be triggered with delay in "Arm Away".
3. If a delayed zone is triggered twice in the same delay, the alarm
system is directly triggered.
Various types of alarms and zone types determines the way the alarm system alerts:
* Valid only if you have an alarm system linked to a central CMS.