13. Technical data
Rated operating voltage U_b 12V DC
Operating voltage range 9V DC bis 15V DC
Max. permissible ripple 1Vpp (peak-to-peak)
Current consumption stand by mode
at 12V DC 190mA
at 10V DC 220mA
Current consumption at 12V DC
by max. screen brightness: - average 230mA - max. 390mA
Current consumption at 10V DC
by max. screen brightness: - average 270mA - max. 480mA
Integrated reader IK2/proX1, IK3/proX2 and mifare DESFire EV1, EV2
Reading distance 0 ~ 3cm for proX and mifare data carrier (*1)
Frequency range, transmission power:
proX1, proX2 125 kHz <10dBµA/m in 10m distance
mifare 13,56 MHz, <0dBµA/m in 10m distance
Screen diagonal (visible) 9" (22,8cm)
Screen format 16 : 9
Environmental class as per VdS II
Environmental class as per EN 50131-3 Class II
Protection class as per EN 60529 IP30
Operating temperature range -5 °C to +45 °C
Storage temperature range -25 °C to +60 °C
Relative humidity 93% non-condensing
Weight 850 g
Dimensions (W x H x D) 218 x 162 x 30 mm
Colour white (similar to RAL 9016), black (similar to RAL 9017)
*1) Specified reading distance on non-metallic mounting surface.
On metallic surfaces, the reading distance may be be reduced slightly.
The specified reading distance can only be garanteed by using data carriers provided by our
company.
When using the encryption method mifare DESFire EV1/EV2, the reading distance may be lower
for EV1 data carriers.
Operating Instructions MB TouchScreen ControlPanel
Hereby, the Novar GmbH declares that the radio equipment MB TouchScreen PanelControl,
Item no. 013080 and 013081 is in compliance with Directive 2014/53/EU.
T he f u ll t e xt o f t h e E U d e c l ar a t io n c a n b e d o w nl o a d e d f r o m o u r h o m e p a g e
https://www.security.honeywell.de/ Service / Download.
14. Certifications
VdS approval no. G121014
VdS2252 Class C / Environmental class II
EN Conformity EN 50131-3: Grade 3
EN 50131-1: Environmental class II
SES Conformity SES-EMA-RL-T2:2021-04
Type B When used in systems according to VdS, EN or SES in the
monitored area, for internal use only.

Other manuals for Honeywell 013080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell 013080 and is the answer not in the manual?

Honeywell 013080 Specifications

General IconGeneral
BrandHoneywell
Model013080
CategoryControl Panel
LanguageEnglish

Related product manuals