Accenta/Optima Engineers Manual
19
1 = Alarm Test
This function tests the alarm function of the Bell, Strobe or Sounder. Pressing the appropriate key
[1-3] toggles the function ON or OFF. Using the [up arrow] also selects the appropriate alarm function.
Pressing [0] turns all alarm outputs to OFF.
Pressing toggles the selected alarm output.
Pressing turns off all outputs and leaves the function.
The outputs are:
1 = Bell, 2 = Strobe, 3 = Sounder
NOTE: To test the Low volume sounder enable option 3 only. To test for a high volume sounder enable both
options 2 and 3 together.
LCD Keypad:
Press for menu Alarm Test.
Press [1] or to enter into first function ON or OFF.
Press the or number [2] or [3] for the other functions.
Press to leave the menu.
LED keypad
The LED is lit when ON.
Press [1] for menu Alarm Test.
Press [1] or to toggle first function ON or OFF.
Press number [2] and [3] for the other functions.
Press to leave the menu.