Accenta/Optima Engineers Manual
46
Specifications
Table 3. Specifications
Specs
8 zones +ve loop, programmable function in each programme
Tamper -ve loop, internal sounders in Day - Fill alarm in Set
PA +ve loop,always active
External siren (Bell Box) outpout 12V adjustable time (1 - 99 mins) or continuous
Strobe output 12 V latching
External speakers 16 Ohms (2 maximum) 260 mA each
Exit/Entry timers Programmable (05 - 990 seconds)
Set output 0 V in Day (sinking 400 mA)
12 V in Set (sourcing10 mA)
Currrent consumption control panel Standby : 80 mA
Alarm: 250 mA
Current consumption (LED keypad) Standby : 40 mA
Alarm: 70 mA
Current consumption (LCD keypad) Standby : 40 mA
Alarm: 70 mA
Low voltage output 13,8 V dc stabilised (+/- 5%), up to 350 mA
Rechargeable battery 12 V, up to 2,1 Ah
Charge voltage 13,8 V dc
Board fuses 1,6 A and1 A-20 mm quick blow
Mains input fuse 125 mA, 250 V type T (anti-surge), type approved to
IEC 127, part 2 sheet 111
Total current output 1 A when supported by a fully charged battery
Mains supply voltage 230 V (+/- 10%) 50 Hz max, load 0,2 A
Ambient operating temperatures 0°C to 40°C
Dimensions H : 200 mm
L : 253 mm
P : 55 mm
Dimensions - LED keypad H : 84,5 mm
L : 122 mm
P : 27,5 mm
Dimensions - LCD keypad H : 105 mm
L : 135 mm
P : 25,5 mm