Accenta/Optima Engineer’s Manual
30
C = View Event Log
1 = LCD Keypad:
The event log gives a display of all the events that have taken place. The events are arranged by date and time.
Up to 250 events can be stored in the memory. When the log reaches 250 events and another event takes
place, the first event drops out. The system is known as FILO (First In Last Out).
To view the event log:
• Press the until you come to the Event Log menu.
• Press or .
• Choose [1] for Event Log in LCD screen.
• The last event (250) appears on LCD screen.
To go forward through the event log in sequence, press .
To go back through the event log in sequence, press the .
• Press twice to leave the menu
To go to a specific event:
• Press the key.
• Key in Event Number you want to see (eg 150).
• Press the key. The event appears on the LCD screen.
• Press again to see further details of the event.
• Press twice to leave the menu option.
Event Log
250>ENG ACCESS
08:44:03 17-May
C>View
Event Log
or
Event Log
1 LCD, 2 LED?
[1]
Event Number?
###
[150]
150>Code entry
09:23:12 04-Jan
Event Number?
150
User 4
C>View
Event Log