Accenta/Optima Engineers Manual
26
Timers (contd)
LCD keypad:
To change the Bell Delay time from 00 to 12 minutes:
Press for menu Timers.
Press [7]or . Option 1 Bell Time appears.
Press [2]. The Bell Delay time in minutes is displayed.
The cursor is under the first digit. Select [1].
The cursor moves to the second digit. Select [2].
To accept the change press then
OR to cancel the change press the key twice.
72 = Bell Delay
This delays the activation of the Bell for the required time. The range is 00-99 minutes. The default is 00
minutes.
NOTE: The Bell Delay delays the bell for one rearm period only. After rearm all alarms are immediate.
7>Timers
Bell Time
Minutes? 00
[2]
71>Bell Time
[7] or
7>Timers
then or
Bell Time
Minutes? 12
[1] and [2]
LED keypad:
To change the Bell Time from 15 to 20 minutes:
Press [7] or for option 71 Bell Time.
Press [1] or for Bell Time in minutes. LED’s 1 and 2
are on.
Select [2] then [0]. LED’s 1 and 2 are on.
To accept the change press then . LED’s 1, 2 and
3 are on.
•OR to cancel the change press twice.