Accenta/Optima Engineers Manual
52
Honeywell Security (UK 64)
Newhouse Industrial Estate
Motherwell
Lanarkshire
ML1 5SB
UK
© Copyright Honeywell SecurityEKZ014400A
Engineer Program Mode [PROG] [9] [9] [9] [9]. To exit Engineer Program Mode [RESET]
0 = Walk Test
1 = Alarm Test
1 = Bell
2 = Strobe
3 = Sounder
2 = Test Outputs
1 = Fire
2 = PA
3 = Intruder
4 = Set
5 = Abort
3 = Set up System Flags
Flag 1
1 = Silent PA
2 = RKP PA
3 = Engineer Reset
4 = PA User Reset
5 = Fire User Reset
6 = Bells in Fire
7 = Zone 7 Fire
8 = Zone 8 Fire
Flag 2
1 = Single Key Set
2 = Strobe On Set
Flag 3
System and Software
Version
4 = Set Up Time and Date
6 = Set Up Zone Names
7 = Set Up Timers
1 = Bell Time
00 - 99 minutes
2 = Bell Delay
00 - 99 minutes
3 = Rearm Count
0 = No rearms
1 - 8 = number of rearms
9 = Always rearm
8 = Set Up Codes
1 = User 1 (Manager)
2 = User 2 (deletable)
3 = Duress (deletable)
4 = Engineer
4-digit code
C = View Event Log
1 = LCD
2 = LED
O = Omit Allow &
Double Knock
1 = Double Knock
2 = Omit Allow
P = Set Up Programs
(1, 2 or 3)
1 = Used Zones (1-8)
2 = Timed Zones
3 = Inhibit Zones
4 = Entry Time (00-99 seconds)
5 = Exit Time (00-99 seconds)
6 = Exit Mode
5 = Languages

Other manuals for Honeywell Accenta

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Accenta and is the answer not in the manual?

Honeywell Accenta Specifications

General IconGeneral
Tamper CircuitYes
Event LogYes
Battery BackupYes
KeypadWired
Power Supply230V AC, 12V DC

Related product manuals