Accenta/Optima User Guide
6
LED Keypad:
Enter your code [0][1][2][3].
The alarm will stop, and the Zone, Tamper (TA) or Attack (PA)
LED’s will come on to show the cause of the alarm.
NOTE: When 2 or more LED’s are on, the flashing indicator shows
the first alarm, and the steady indicators show the second and
subsequent alarms.
Press [RESET].
If the Zone, Tamper (TA) or Attack (PA) LED’s go out and
the Day LED comes on then the system has been reset.
If any of the LED’s continue to flash then the system has been pro-
grammed to be reset by the installer. In this case you must call the
installer to reset the system.
If all LED’s light steady (not flashing), and the keypad stops working,
then the system has entered a fault-lockout. You must call the installer
to rectify this fault.
How to Omit Zones
If you cannot set the alarm system because a detector is faulty and in constant alarm you may need to omit its
zone from the alarm system. A zone which has been omitted cannot cause an alarm. Omitted zones will be
restored after the system is unset.
Before a zone can be omitted it has to be enabled by the installer as a Used Zone and as an Omit Allow
zone.
LCD Keypad:
Enter your [4-digit code] to start the exit procedure (for
more information see How to Set the System).
Press [OMIT] and the exit beep tone will stop, and the first
used zone that can be omitted will appear on the display.
Press the zone [number] or [up arrow] to be omitted. The
display will now show the zone as omitted. If a flat reject
tone is heard, then the zone cannot be omitted.
Press [SET] or allow the system to continue to set.
NOTE: Zn = Zone number
[0][1][2][3]
Power
Attack
Tamper
Day
Zones
1
23
4567
8
[RESET]
Power
Attack
Tamper
Day
Zones
1
23
4567
8
[4-digit code]
Program 1 SetProgram 1 Set
Program 1 SetProgram 1 Set
Program 1 Set
Program 1 SetProgram 1 Set
Program 1 SetProgram 1 Set
Program 1 Set
Zn: [Descriptor]Zn: [Descriptor]
Zn: [Descriptor]Zn: [Descriptor]
Zn: [Descriptor]
Not OmittedNot Omitted
Not OmittedNot Omitted
Not Omitted
[OMIT]
Zn: [Descriptor]Zn: [Descriptor]
Zn: [Descriptor]Zn: [Descriptor]
Zn: [Descriptor]
OmittedOmitted
OmittedOmitted
Omitted
[4]
[SET]
** SYSTEM SET **** SYSTEM SET **
** SYSTEM SET **** SYSTEM SET **
** SYSTEM SET **
How to Omit Zones

Other manuals for Honeywell Accenta

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Accenta and is the answer not in the manual?

Honeywell Accenta Specifications

General IconGeneral
Tamper CircuitYes
Event LogYes
Battery BackupYes
KeypadWired
Power Supply230V AC, 12V DC