5
LED Keypad:
The Day LED should be on.
Power
Attack
Tamper
Day
Zones
1
23
4567
8
• Enter your code [0][1][2][3]. The exit beep starts.
• Press the [PROG] key. The exit tone stops and the zone
LED’s 1 to 3 come on.
• Select part-set program [2] or [3]. The system will set after a
short time. The Day LED goes out.
NOTE: There will be no exit beeps if Silent Timed exit mode was
programmed.
Power
Attack
Tamper
Day
Zones
1
23
4567
8
[0][1][2][3] then [PROG]
[2 or 3]
Power
Attack
Tamper
Day
Zones
1
23
4567
8
If your system goes into alarm then be aware that intruders may be in
the premises. Seek assistance before investigating the cause of the
alarm.
LCD Keypad:
• Enter your code [0][1][2][3]. The alarm will stop.
• The screen alternates showing what caused the alarm and
prompting for user reset
When two or more alarms have occured, the first alarm will have an
F below the zone number, Tamper or PA. Subsequent alarms will
have a 1 indicating where the alarm has taken place.
• Press [RESET]. The system resets and goes into day mode if
there are no open Tampers, PA or Fire zones to cause a fault
lockout.
The system can be reset by the user only if the installer has pro-
grammed it to do so. If the message Engineer Restore Required
appears on screen then the user will have to contact the installer.
• After 30 seconds the set mode display appears.
How to Silence an Alarm and Reset the System
How to Silence an Alarm
[RESET]
12345678 TP12345678 TP
12345678 TP12345678 TP
12345678 TP
00100000 0F00100000 0F
00100000 0F00100000 0F
00100000 0F
[0][1][2][3]
RestoredRestored
RestoredRestored
Restored
by Userby User
by Userby User
by User
Enter Your CodeEnter Your Code
Enter Your CodeEnter Your Code
Enter Your Code
User RestoreUser Restore
User RestoreUser Restore
User Restore
Press ResetPress Reset
Press ResetPress Reset
Press Reset
SundaySunday
SundaySunday
Sunday
01-Jan01-Jan
01-Jan01-Jan
01-Jan
14:10 14:10
14:10 14:10
14:10