EasyManua.ls Logo

Honeywell CT30 XP Series - S0703-SR (Standard Range) Imager

Honeywell CT30 XP Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CT30 XP Mobile Computer Series User Guide 107
Note: To learn about changing the symbology settings, see Change the Scanner Settings on
page 34.
S0703-SR (Standard Range) Imager
The depth of field measurements used the following parameters:
Distances are measured from the front of the Imager.
+23°C (+73°F), 0 lux for guaranteed, 200 lux for typical.
Photographic quality codes
Note: Time to Read and Depth of Field are impacted if the barcode symbol is at the edge of
the image.
Guaranteed Specs
Interleaved 2 of 5 Enable Digimarc Disabled
Matrix 2 of 5 Disable TLC 39 Disabled
MSI Disable
Telepen Disable
Trioptic Disable
UPC/EAN Enabled
UPC-A Enabled
UPC-E Enabled
1D Symbologies 2D Symbologies Postal Codes
Default Default Default
Focus Standard Range
Symbology Near Distance Far Distance
5 mils Code 39 mm 79 270
in. 3.11 10.63
10 mils Code 39 mm 40 425
in. 1.57 16.73
20 mils Code 39 mm 44 674
in. 1.73 26.53
13 mils 100% UPC-A mm 44 493
in. 1.73 19.41
15 mils Code 128 mm 42 572
in. 1.65 22.52
10 mils Data Matrix mm 83.1 236
in. 3.27 9.29

Table of Contents

Other manuals for Honeywell CT30 XP Series

Related product manuals