IMPROPER INSTALLATION OF FF-SB SERIES LIGHT CURTAIN
Use figure 3-6 wiring diagram to ensure external relay monitoring by the interface.
Failure to comply with these instructions could result in death or serious injury.
IMPROPER SYSTEM PERFORMANCE
Ensure independent stop circuit safety relays have mechanically linked contacts that prevent contact
overlapping in the event of a welded contact.
Failure to comply with these instructions could result in death or serious injury.
Figure 3-6 Wiring Diagram to replace Original Version FF-SB Series configuration with CE Version
of FF-SB Series configuration (except FF-SB12R02)
B3
B4
B5
C3
Not Connected
dditional output
channel, may be
used to annunciate
to PLC
R2
HOT
R2
NEUTRAL
RECEIVER
Jumper Link position
on the Receiver
Power Board (factory
setting)
*Two arc suppressors are provided with the light curtain.
The cycle-start push-button is the normal push-button used to start the machine cycle and not an additional
button for the operator.
*