The menu structure and programming of the Alarm Monitoring options are identical to the SIA format.
Refer to option 2 = SIA for programming details.
15 Backup Module
This option allows another module to become the primary communication module if a line fail is detected on
the on-board telecom. There are 6 options:
1 = Off; 2 = Ext Telecoms; 3 = Ext RS232; 4 = ISDN; 5 = Ethernet; 6 = Int RS232 1.
16 Force V.21
Option not available
17 SMS
The SMS option is available on Galaxy panels with V4.00 and above software and Telecom modules with
V5.xx and above software. This option generates and transmitts SMS text messages, for events generated by
the Galaxy panel.
1=Mobile No.
This is a 22 digit telephone number and is the mobile phone number of the recipient of the message.
2=Centre No.
This is a 22 digit telephone number and is the phone number of the SMS centre. The default is different for
each operator.
3=Format
The options for this menu are:
1=TAP
For mobile phones (UK)
2=UCP (SMS)
For mobile phones (outside UK)
3=UCP (Minicall)
For alpha pagers
4=UCP (Numeric)
For numeric pagers
4=Site ID
This is a 16 character alphanumeric string and is used to identify the panel/site sending the message. If the
format is UCP (Numeric), then the site ID is numeric only, and only the first four characters are sent out.
5=Password
This is a 16 character string and is an optional field required by some paging centres.
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals