Galaxy 3 Series Programming Manual
17
Section 5: Display Options
Option 21 – Display Zones (Quick Menu Option 3)
Selecting and entering the Display Zones option shows the first zone on the system. Other zones may be
viewed by pressing the A and B keys or by entering the zone number directly.
The top line displays:
the address;
the group assigned — if the group mode is enabled. Only the zones assigned to the user’s group are
displayed.
the zone function alternating with the status — open, closed, high resistance, low resistance, tamper short
or tamper open circuit or masked.
The bottom line shows:
the zone descriptor (if used);
by pressing the # key the bottom line changes to show the circuit resistance in Ohms, if using a hardwired
RIO and the RIO (not zone) voltage, pressing the # key returns the bottom line to the zone descriptor.
A printout of all the zones is available from this option by pressing the key; pressing the esc key aborts the
printout.
NOTE: A serial printer must be connected to the Galaxy panel via a printer interface module, an RS232
interface module, or the on-board RS232 serial port.
21 - Display Zones

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals