Galaxy 3 Series Programming Manual
30
Escaping from Engineer Mode
1. Return to the engineer banner.
2. Enter the engineer code
3. Press the esc key
The Galaxy begins the exit engineer mode procedure by checking the integrity and security of the system:
CHECKING FOR TAMPERS — the panel calculates that the standby battery connected to it is capable of
operating the system for the required period (as entered in the Standby Battery parameter — refer to
option 51.37). The system then verifies that there are no tamper conditions present on the panel, the
modules or the zones.
SYSTEM MODULES — if there are no tamper conditions the Galaxy checks the number of modules con-
nected to the system:
If no modules have been added or removed, “ NO MODULES ADDED, ESC TO CONTINUE” is
displayed. Pressing esc returns the system to the normal banner.
If modules have been removed they are reported as missing; the engineer is prompted to view the missing
modules and to remove them from the system by pressing the ; a warning is given before the module is
removed. Press the ent key to confirm the removal of the module. Once all missing modules are removed,
the Galaxy reports the previous and current number of modules connected to the system, before returning
to the normal banner.
If modules have been added, the Galaxy reports the previous and current number of modules connected
to the system, before returning to the normal banner.
If the esc key is pressed at any time during the exit engineer mode procedure, the procedure is aborted and
the Galaxy returns to the engineer mode. This return may take several seconds to complete.
Manager Code
The manager is authorized to:
modify the manager PIN — the manager PIN cannot be deleted — and assign the MAX features
to the code.
If authorized via menu option 48.2 the manager is also authorized to:
program the User Code options of each of the user codes;
allocate other codes to the manager type (3.6);
NOTE: The manager PIN can be reset to the default code (12345) by the engineer and remote code using
the Reset Mgr (Manager) parameter (refer to option 51.21).
The manager code defaults to group choice when groups are enabled. The manager is able to toggle
the group choice option on and off (using the key) as required.
The manager code defaults to accessing the full menu (option 11 – 71). To access the quick menu (options 0 –
9), remove the assigned to the manager in the Modify Level option.
42 - Codes (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals