Galaxy 3 Series Programming Manual
87
Keypad Outputs
The keypad outputs are fully programmable. The address of the keypad output is the keypad address pre-
fixed with a star, for example the output for keypad 06 is 06. The function of keypad outputs default to
Entry/Exit Horn.
The valid addresses of the keypads on each of the panels and the respective output addresses are indicated in
the following table:
Table 20. Addresses of Valid Keypad Outputs
It is possible to add additional keypads at any unused comms module addresses (B, C, D and E) as detailed
in the following NOTE. These must be standard keypads. An engineer keypad can also be used at address F.
NOTE: On Line 1, keypad addresses B, C, D and E are not available if the Ethernet,
ISDN, RS232 or Telecom modules respectively are fitted.
Control Horn (
99)
The control unit horn output - addressed as 99 - is fully programmable.
Attributes
The attributes can be stepped through by pressing the A or B keys or directly selected by pressing the at-
tribute number (1–4). Once the required attribute is on display, press the ent key to gain access for modifica-
tion.
Once the attribute has been assigned press the ent key to save the programming and return to the attribute
selection level. Pressing the esc key at any time when assigning attributes aborts the programming and returns
to the attribute selection level.
1 = Output Function
Entering the Output Function attribute displays the address and the current function of the selected output
along with the output function reference number. The output functions can be stepped through, forwards or
backwards, using the A and B keys. Alternatively, a function can be directly selected by entering the function
reference number, for example, entering 16 displays output function 16 = FIRE.
Once the required output function is displayed, it is assigned to the output by pressing the ent key.
53 - Program Outputs (cont’d)
Panel Line Address Output Addresses
3-48 1 0 – 2, B, C, D, E & F (NOTE) 10-12, 15-19
3-144 1 0 – 2, B, C, D, E & F (NOTE) 10-12, 15-19
2 0 – 6 & F 20-26, 29
3-520 1 0 – 2, B, C, D, E & F (NOTE) 10-12, 15-19
2 0 – 6 & F 20-26, 29
3 0 – 6 & F 30-36, 39
4 0 – 6 & F 40-46, 49

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals