Galaxy 3 Series Programming Manual
131
Groups Setting
NOTE: This option is only displayed if the groups have been enabled (refer option 63.1)
Each of the events are signalled to Primary IP/Port Numbers programmed in menu option 56.4.2.2 and the
account number programmed in 56.4.2.4. However, each group can be programmed to transmit event
details to a unique IP address and port number, with a unique account number. On selecting the 2=Group
Settings option the first group is displayed. Select the required group to be modified using the A/B keys
and press ent. 1=Account No. is displayed
1 = Account No.
By default the account number programmed in option 56.4.2.4 will be entered in this field. To assign a
unique account number to the group selected use the B key to erase any existing numbers and enter the
new number. The account number should be between four and six digits long. Press the ent key to save
the programming and return to the previous menu level.
To modify the IP address which events from a specific group will be signalled to press the A or 2 keys,
then press ent.
2 = IP Address
By default the IP address programmed in option 56.4.2.2 will be displayed. To programme a new IP
address use the B key to erase any existing programming and enter the new IP address to which the
events are to be sent. Press ent to save the new address and return to the previous menu level.
To modify the Port No. which events from a specific group will be sent press either the A or 3 keys,
then press ent.
3 = Port No.
By default the Port No. programmed in option 56.4.2.2 will be displayed. To programme a new port
number use the B key to erase any existing programming and enter the new port number. Press the ent
key to save the new address and return to the previous menu.
2 = Microtech
Microtech format is a protocol that transmits detailed point id information to a PC, which has the Galaxy
Alarm Monitoring application installed and running.
The level of information supplied is similar to SIA level 3.
The menu structure and programming of the options are identical to the SIA format. Refer 1=SIA for pro-
gramming details.
2 = Primary IP
The Primary IP defines the receiver destination details for the primary alarm transmission path. The destination
is made up of an IP address and a port number. To programme the IP address press ent. If groups are ena-
bled the information programmed for the primary IP and port numbers is automatically copied to all groups.
1 = IP Address
Enter the IP address of the primary receiver. The address will be in the form XXX.XXX.XXX.XXX. The dot
separator will be automatically added after each sequence of three numbers or can be manually added by
pressing the * key. To save the address and return to the previous menu level press ent. To programme the
port number of the primary destination receiver press either 2 or A, then press ent.
Note: This number must be programmed, even if groups have been enabled and all groups have a pro-
grammed IP address. This is the IP address used for all system wide events.
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals