Galaxy 3 Series Programming Manual
137
4 = Any
When selected the Ethernet module monitors all transmission paths. If a supervision failure is detected in any
of the paths a line fail condition will be activated.
5 = All
When selected the Ethernet module monitors all transmission paths. If a supervision failure is detected in all of
the paths a line fail condition will be activated.
08 = SIA Control
When using the SIA control command protocol for integration purposes the IP address of the computer
sending the SIA control commands should be entered in this field to ensure that only commands from a com-
puter with the programmed IP address will be recognised by the Ethernet module.
1 = IP Address
The address will be in the form XXX.XXX.XXX.XXX. The dot separator will be automatically added after
each sequence of three numbers or can be manually added by pressing the * key.
09 = Encrypt
The Ethernet module supports a high level 128bit encryption algorithm for all communication options. This
option allows encryption to be enabled/disabled for each of the communication options.
1 = Alarm Report
This option controls encryption for the Primary and Secondary alarm transmission paths. Default is disabled.
0 = Off
If selected encryption is disabled for the Primary and Secondary alarm transmission paths.
1 = On
If selected encryption is enabled for the Primary and Secondary alarm transmission paths. In order for data to
be received when this option is selected the receiver must support decryption.
2 = Remote Access
This option controls encryption for the Galaxy Gold remote servicing sessions. Default is disabled.
0 = Off
If selected encryption is disabled for the Galaxy Gold remote servicing sessions.
1 = On
If selected encryption is enabled for the Galaxy Gold remote servicing sessions. In order for data to be re-
ceived when this option is selected the receiver must support decryption.
3 = SIA Control
0 = Off
This option controls encryption for communications between the Ethernet module and remote PC using the
56 - Communications (cont’d)

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals